The same variable name can exist in two different sections.

svxlink conf example

Some sound cards also sound very bad at 8kHz due to insufficient anti-alias filtering or resampling effects.

These, often cheeper, sound cards sound OK at 48kHz. Supported sampling rates are:and LINKS Enter here a comma separated list of section names that contains the configuration information for linking logics together see Logic Linking. The SvxLink server can handle more than one logic core and so can be connected to more than one transceiver. The configuration variables below are common to all logic types. Configuration variables that are specific to a certain logic core type are described below in a section of its own.

TYPE The type of logic core this is. The documentation for the specific logic core type you want to use describe what to write here. RX Specify the configuration section name of the receiver to use.

All configuration for the receiver is done in the specified configuration section. TX Specify the configuration section name of the transmitter to use.

All configuration for the transmitter is done in the specified configuration section.

Mazeda internet

This tells SvxLink which modules to actually load on startup. The purpose of the short identification is to just announce that the station is on the air. Typically just the callsign is transmitted. For a repeater a good value is ten minutes and for a simplex node one time every 60 minutes is probably enough.

If unset or set to 0, disable short identifications. The purpose of the long identification is to transmit some more information about the station status new voice mails etc. The time of day is also transmitted.Letters are mapped to the corresponding characters and these correspond to the corresponding numbers.

All other characters are assigned to the digit 1. A search command begins with an asterisk, followed by the callsign code. Since the codes are not unique, you will be offered a list of stations found that correspond to the pattern you are looking for and from which you can choose.

SVXLINK.CONF

The star sign corresponds to a kind of joker, i. For more information on the echo link system, please visit the EchoLink website. Foren Members Posts Register Login.

Plc programming questions

To establish a connection simply enter the node number of the station followed by a hash. To disconnect again, send a single hash.

It is the same image as most phones. Network address from which a lekaler Connect is allowed, e. Regex syntax, EchoLink stations whose connect requests are ignored no information to the remote station.

Regex syntax, EchoLink stations whose connect requests are rejected information to the remote station. Regex syntax, if defined, will only be established to those stations that match the Regex definition. Regex syntax, if defined, will prevent outgoing connection establishment. The requesting station receives information that the connection will not be established. All stations in conference mode are blocked. If a station connects to a conference after the connection to its own station has already been established, the connection to this station is interrupted disconnected.

If a station is connected too often, the number of attempts can be limited, a new connection attempt is then rejected. The password for logging in to the EchoLink directory service in plaintext! SPEEX requires a higher computing power, which may lead to interrupted audio output on weak systems. If set, the connection to the configured EchoLink proxy server will be established.GitHub is home to over 40 million developers working together to host and review code, manage projects, and build software together.

Skip to content. Permalink Dismiss Join GitHub today GitHub is home to over 40 million developers working together to host and review code, manage projects, and build software together.

Sign up. Branch: master. Find file Copy path. Cannot retrieve contributors at this time. Raw Blame History. B remotetrx is the SvxLink remote transceiver server. This man-page describe the configuration file format for it. P The RemoteTrx application can handle more than one transceiver at a time. You may for example want to handle both a 2m and a 70cm receiver on a site.

svxlink conf example

One sound card is sufficient for doing this since the left channel can be used for one receiver and the right channel can be used for the other receiver. Each transceiver have an uplink that is used to interface to the main SvxLink server. It is also possible to have an uplink via RF but the functionality is then limited. P The term "uplink" might be a bit confusing for some people.

In this case it does not refer to any specific direction in which the data or audio is flowing. It's just the name for the link up to the main SvxLink server.

P RemoteTrx look for configuration files in a number of places. First it tries to find a user specific configuration file. It will look for a user specific configuration file in two places:. If no user specific configuration file can be found, remotetrx will look for the system wide configuration file. B --config command line option may also be used to specify an arbitrary configuration file. The configuration file is in the famous INI-file format. A generic example of how such a file might look like is shown below.

P The same variable name can exist in two different sections. Here is the description of all configuration variables that remotetrx understands. The configuration variables are described section for section. B TRXS This configuration variable specify a comma separated list of transceiver configuration sections.

If a relative path is specified, the path will be relative to the directory where the main configuration file is at. All files in the specified directory will be read as additional configuration. Filenames starting with a dot are ignored. The format string is in the same format as specified in the. BR strftime 3 manual page. UTF8" will give you swedish timestamp representation. Other examples of format specifiers are:. SvxLink always work with a sampling rate of 16kHz internally but there still are som benefits from using a higher sampling rate.

On some sound cards the filters look pretty bad at 16kHz and the amplitude response will not be uniform which among other things can cause problems for the software DTMF decoder. Some sound cards also sound very bad at 16kHz due to insufficient anti-alias filtering or resampling effects.You seem to have CSS turned off. Please don't fill out this field. Please provide the ad click URL, if possible:. Help Create Join Login. Operations Management. IT Management. Project Management.

Services Business VoIP. Resources Blog Articles Deals.

ConfigExamples

Menu Help Create Join Login. SvxLink Brought to you by: sm0svx. Oh no! Some styles failed to load. Sign Up No, Thank you. Thanks for helping keep SourceForge clean. X You seem to have CSS turned off. Briefly describe the problem required :.

Bmw 318i fuel pump problems

Upload screenshot of ad required :. I've just downgraded to You will get that by specifying "gpio31" instead of just "31" in the configuration. The change was made to support more boards. If you wonder about changes in between releases, be sure to check out the ChangeLog for the release. You can find the This enables the use of any pin naming scheme. It's a bit hackish as it uses the sysfs files to toggle the GPIO value on a specified pin, but this method allows for a non-root user to change the value of the pin by chowning the proper file to svxlink.

Once set, start svxlink and connect to it. On transmit the specified GPIO pin will be brought up 3. Please reference the Nabble website for more info on this patch for However, in version This man-page describe the SvxLink server configuration file format. SvxLink look for configuration files in a number of places.

First it try to find a user specific configuration file.

svxlink conf example

The --config command line option may also be used to specify an arbitrary configuration file. The configuration file is in the famous INI-file format. A generic example of how such a file might look like is shown below.

The same variable name can exist in two different sections. Here is the description of all configuration variables that SvxLink understands. The configuration variables are described section for section. Specify where the SvxLink modules can be found.

Echolink Pi Naked Node with SVXLINK Part 1

If that also fails a hardcoded default will be used. Leaving this variable unset should work in most cases. Specify a comma separated list of logic cores that should be created.

The logic core is the thing that ties the transceiver and the voice services modules together. It contains the rules for how the radio interface should be handled. The specified name of a logic core must have a corresponding section specified in the config file.

This is where the behaviour of the logic core is specified. Specify the path to a directory that contain additional configuration files. If a relative path is specified, the path will be relative to the directory where the main configuration file is at. All files in the specified directory will be read as additional configuration.

Filenames starting with a dot hidden files or not ending in. This variable specifies the format of the timestamp that is written in front of each row in the log file.

The format string is in the same format as specified in the strftime 3 manual page. UTF8" will give you swedish timestamp representation. Other examples of format specifiers are:.

SvxLink always work with a sampling rate of 16kHz internally but there still are som benefits from using a higher sampling rate. On some sound cards the filters look pretty bad at 16kHz and the amplitude response will not be uniform which among other things can cause problems for the software DTMF decoder. Some sound cards also sound very bad at 16kHz due to insufficient anti-alias filtering or resampling effects.This man-page describe the SvxLink server configuration for the EchoLink module.

The EchoLink module is used to connect to other EchoLink stations. There are a couple of configuration variables that are common to all modules. The documentation for these can be found in the svxlink. Here is the description of all module specific configuration variables that the SvxLink EchoLink module understands. Use this variable very carefully. Connections originating from the given subnet will not be checked against the EchoLink directory server.

A typical use of this is if you want to connect to your own svxlink server and both the server and you are behind a IP masquerading firewall. Drop all incoming connections where the remote callsign match this regular expression. No message will be sent to the remote station notifying about the drop.

The connection will just be ignored. Reject all incoming connections where the remote callsign match this regular expression. A message will be sent to the remote station indicating that the connection was rejected. Only accept incoming connections where the remote callsign match this regular expression. Reject all outgoing connections where the remote callsign match this regular expression.

When this is set to 1, reject all incoming connections where the name of the remote station ends in the word CONF. This blocks connects from stations that are in conference mode. When a station enters conference mode after connecting, and transmits towards us, it will be disconnected as well. If a station connects to often it can be blocked for a configurable time span. Only accept outgoing connections where the remote callsign match this regular expression.

A space separated list of IP addresses or names of the EchoLink directory servers to use.

Samsung bn64 remote

The specified servers will be tried in order until one is found that works. SvxLink will then stick to that server.

If that server fail, SvxLink will again try the next server in the list and when the end of the list has been reached, the search start from the beginning again. Hostnames that resolve to multiple IP addresses, like servers.

Oh no! Some styles failed to load. 😵

The location of the station. Note: In the default configuration file the value of this configuration variable starts with "[Svx]". If set, connect to the given EchoLink proxy server host. All EchoLink connections, both incoming and outgoing, will then go through the proxy. Default is Set the EchoLink proxy password used when connecting to an EchoLink proxy server.

This may be needed if the computer is fitted with more than one ethernet interface and EchoLink should only be used on one of them. The maximum number of stations that can participate in a conference QSO on this node. If more stations try to connect, the connect request will be rejected.

Set the language to use for announcements sent to remote EchoLink stations. If not set, it will be the same as the one chosen for the logic core. The reason for setting this up may be that you want one language for the core and another language for annoncements sent to remote EchoLink stations.This man-page describe the configuration file format for it. The RemoteTrx application can handle more than one transceiver at a time.

You may for example want to handle both a 2m and a 70cm receiver on a site. One sound card is sufficient for doing this since the left channel can be used for one receiver and the right channel can be used for the other receiver. Each transceiver have an uplink that is used to interface to the main SvxLink server. It is also possible to have an uplink via RF but the functionality is then limited.

The term "uplink" might be a bit confusing for some people. In this case it does not refer to any specific direction in which the data or audio is flowing. RemoteTrx look for configuration files in a number of places. First it tries to find a user specific configuration file.

Msg exe send to all users

The --config command line option may also be used to specify an arbitrary configuration file. The configuration file is in the famous INI-file format. A generic example of how such a file might look like is shown below. The same variable name can exist in two different sections.

Here is the description of all configuration variables that remotetrx understands. The configuration variables are described section for section. This configuration variable specify a comma separated list of transceiver configuration sections.

Specify the path to a directory that contain additional configuration files. If a relative path is specified, the path will be relative to the directory where the main configuration file is at. All files in the specified directory will be read as additional configuration. Filenames starting with a dot are ignored.